LRAFT QRs (QUALITATIVE REQUIREMENT)/SPECIFICATION OF INFLATABLE TENT 14FEET X10 FEЕТ

LRAFT QRs (QUALITATIVE REQUIREMENT)/SPECIFICATION OF INFLATABLE TENT 14FEET X10 FEЕТ

Category: Collapsed Structure Search & Rescue (CSSR) Equipment

Color: black,

Size: 15m,

The specification covers the requirements of design, manufacture, testing, supply and commissioning of inflatable tent with all standard accessories during rescue operation at the site of the accident. S.N TECHNICAL PARAMETERS 01 Outer Width 02 Outer Length 03 Inner Height 04 Door Entrance Height 05 Doors Cum Windows 06 Anchoring 07 re Accessories INFLATABLE TENT 14X10 FEET (04 PERSONS) 10 Ft (-2 %,+ 5% tolerance) 14 Ft (-2%,+ 5% tolerance) 9.84 Ft (3 Mtr) (± 10% tolerance) 6 Ft (1.83 Mtr) (± 10% tolerance) 06 Numbers with Mosquito net & Insect net along with door curtain. Doors -02 Door- 6 Ft height X 3 Ft width ( -2%,+5% tolerancе) Windows - 04 Window-1.97 Ft height X 1.80 Ft width )- 2%,+5% tolerance) Roll able and divisible windows and entrances 08 Numbers (small angle iron picket 610 mm and weight 1.78 kg (± 05% tolerance). With 8 Numbers tie rope of 10 meter length, having minimum dia- 6 mm to 9mm each for Anchoring) i) Repair kit (Including swatches- 03 Numbers, Adhesive- 02 bottles & 250 ml adhesive solution) ii) AC blower (weight-1.7 KG) Pipe- length-60 Inch & pipe Weight- 300 GM) and DC blower weight- 2.2 KG), Pipe length- 53 Inch, pipe weight- 100 GM) with Battery (weight-14 Kgs) iii) Double faced sledge Hammer (Weight 2 Kg.) with handle length-24 inch, width-3 inch,- Rubberized Mallet light weight material) iv) Carry Box empty for Tent (Fiber- 12.8 Kgs (±10% tolerance) & Empty Accessories Box-13 Kgs (± 10% tolerance) v) One valve to inflate 1 Quee Ave Brieas Lhely lethan CRPA NITRA Lyador 2 vi) One number safety valve to relieve over pressure vii) Bottom Ground sheet-PVC coated Polyester fabric 550 g/m² (GSM) (01 number 15.5 KG) viii) Non woven carpet 300 g/m² (GSM) ix) Digital manometer: Solar Power. 08 Weight of Tent only 55 Kg ± 10% 09 Maximum time required for complete erection of tent. With AC blower < 4 minutes & with DC Blower 10 minutes With the help of two (02) persons. 10 Colour Grey, white, Olive green or as per user requirement. 11 Fabric Material i) Top cover Fabric: PVC coated Polyester Rip Stop, Fabric 300 g/m² (GSM) (± 40 GSM) ii) Air Inflated Beam Fabric: PVC coated Polyester 850 g/m² (GSM) (± 40 GSM). iii) Floor/Ground Sheet attached tent: Polyester Rip Stop Fabric 300 g/m² (GSM) (± 40 GSM) iv) Beam fabric, Ground fabric, Cover fabric should be FR (Fire Retardant) and water proof. No iron poles are required in this tent v) Cotton Liner:- Cotton Liner should be for roof & Doors 12 User manual Required In two languages Hindi and English 13 Valve for inflation One Valve (Inflation and deflation type) 14 Total collapse time of Tent Tent shall stand up to 72 Hrs from the day of Inflation in 02 conditions environmental condition i.e Quu BP@RD i) At a temperature range of 0°C to 50°C. ii) At a temperature range of-10°C to 50°C. The pressure of the beam will vary between 60 MBAR to 200 MBAR for both temperatur conditions. If atmospheric condition varies, it is suggested to top up the air intermittently as and when required. The test report should be submitted to authenticate the temperature range. BSP) 2 h CRPA NITRA Abyode 17BP 1. Quality of sewing thread a) Material b) Number of ply c) Strength As per 15 Testing Report required from NABL Lab or NABL accredited Lab 16 Stitching and pasting procedure Beam fabric, ground fabric and cover fabric for tear and tensile shall be tested in Govt Lab /NABL accredited Lab Single needle stitching and heat sealing pasting. 17. SEWING THREAD, SLIDE FASTENER AND HOOK & LOOP TAPE 2. Slide Fastener Polyester 25 N (minimum) fastener IS:1670 amended the year 2002 - 3 ply Slide shall be IS a) Material b) Color c) Designation d)Slider Lock Type e) Remeshability of Fastener f)Reciprocating movement of slider under Load g)Security of Interlocking of Textile chain crosswise strength and Further Load h)Security of Attachment of Puller to the slider i)Security of Slider Lock holding j) Colour fastness to washing k)Colour fastness to light 1100 N (minimum) 350 (Minimum) 60 N (Minimum) 4 or better 4 or better Nil 14181:2002 Reaffirmed 2019 covered with a flap of 2.5 Cms(centimeters) MS width Plastic Visually matching to the tent color. Heavy special Non Lock/Reversible non lock Remeashable with slide movement over the disengaged chain 1000 Cycles Flammability as per guidelines of IS 11871 (Vertical method) BPRED (BSF) A 3 dh CRPP GSN Ste NITRA Abmaday TP 03 4 a) Material HOOK AND LOOP TAPE IS 8156: 2014 - Reaffirmed Nylon 66 Nylon 6/Nylon 66 2019 Hook - Loop b) Color c) Strength of Tapе Sheer strength Peel Strength After endurance sheer strength Dot tear strength o Hook oLoop Guidance parameters Visually matching to the 03 4 a) Material HOOK AND LOOP TAPE IS 8156: 2014 - Reaffirmed Nylon 66 Nylon 6/Nylon 66 2019 Hook - Loop b) Color c) Strength of Tapе Sheer strength Peel Strength After endurance sheer strength Dot tear strength o Hook oLoop Guidance parameters Visually matching to the color of tent 900g/cm2(minimum) 200g/cm(minimum) Shall not 675g/cm² 25 N 25N be less than The inner tubes shall be thick, with a 850 g/m² (GSM), which creates a really solid structure when fully inflated. The diameter of these inner tubes can hold a high air pressure at least of 1.20 PSI. 5 Specification and rating all materials being used of 18. BEAM FABRIC SPECIFICATION To validate specifications, Need to submit the Government Lab/NABL accredited Lab test reports, comprising all specification parameters S.No. Properties Standard Method Value 1 Strip Breaking Strength Warp wise Weft wise IS 7016 PART II:2015 WARP (minimum) 150 Kgf/5cm IS 7016 PART II:2015 WEFT(minimum) 100 Kgf/5cm 2. Tongue Tear Strength Across Warp Across Weft IS 7016 PART III 1981, WARP (minimum) 20 kgf Method AI: Reaffirmed 2019 WEFT(minimum) Average time of flame spread in Sec 20 Kgf shall not ignite (Zero seconds) No leakage 3. Fire retardant or Flammability IS 11871:Method B :2004 4. Determination of Resistance to Penetration by water IS 7016 partVII :2009 aj The duration of the test: 1 Hr. b) Column height: 90 Cms 4 BPARD L CaSA) dbl NITRA lefaon CRPR SheNSG 141BP 4 19. COVER FABRIC SPECIFICATION (TABLE FORMATTING IS ALSO DONE S Properties Standard Method Value 1. Finished Coating Weight IS 7016 PART-I Reaffirmed 2019 GSM 300g/m² (± 40) 2. Strip Breaking Strength Warp wise Weft wise IS 7016 PART-II :2015 WARP (minimum) 40 Kgf/5 cm WEFT(minimum) 40 Kgf/5 cm 3 Adhesion Coating to Base Fabric Warp wise IS 7016 PART-V Reaffirmed:2019 WARP (minimum) 2.5 Kgf/5 cm