SPECIFICATION FOR HUMAN LIFE DETECTOR TYPE-I
Category: Collapsed Structure Search & Rescue (CSSR) Equipment
Color: Red,
Size: ,
GENERAL:
Life detector a seismic/acoustic listening device, light weight and easy to carry, designed
specially to detect and locate trapped, live victims in collapsed structures caused by earthquakes,
explosion, landslides, construction cave-ins or mine disasters and should include the control unit,
sensors, sensors spikes, connecting cables and spools, Magnetic Clamps, Headphones, intercom
probe, AC power supply battery pack and carry bag (for control unit) with all required
accessories.
The Life Detector should be provided with not less than 6 sensors. 4/6 sensors.
TECHNICAL SPECIFICATIONS
(F) MAIN UNIT
INPUT OF SENSOR/INTERCOM/PROBE
Seismic sensor input impedance : > 6K Ohms
Intercom probe input impedance: > 3 K Ohms
HEADSET OUTPUT
For headphones :
1
/4" stereo jack
Output power, variable : 0.13 W/60 Ohms
FREQUENCY RANGE
1 Hz to 3000 Hz
FILTERS (FIXED SWITCH ABLE)
"Rumble" : High pass 100 Hz
"PWR" : Notch 50 Hz and 60 Hz
"Hiss" : Low pass 600 Hz
SIGNAL DISPLAY
LED Bar graph any 2 channels or sum of all channel, range 60 db.
(I) SESMIC/ ACCOUSTIC SENSOR (POSITION INSENSITIVE)
Frequency Range : 1 Hz to 300 Hz
Shock resistant : > 1000 g
(J) © POWER SUPPLY
Battery operated, low battery alert: Lithium ion rechargeable battery type”. Appropriate
perating time at approx. 20 deg.C:>20 hrs
Ext. DC Input
AC/DC converter,
AC line frequency
: 10.8 to 28.8 VDC
: 47 to 63 Hz
Nominal AC line voltage : 100 to 240 VAC
(K) AMBIENT TEMPERATURE
Storage and transport : -20 degree to + 70 degree C
Nominal operating range : -15 degree to + 60 degree or more.
Each system /life detector should contain following :-
1) Sensor spike - 6 Nos
2) Magnetic sensor clamp – 2 Nos
3) Lithium ion rechargeable battery stick -2 No s
4) Lithium ion battery stick charger 01 Nos
5) Power supply 01 Nos
6) Carry bag for Interface unit 01 Nos
7) lanyard strap 01 Nos
8) Cable connecter cap ,pack of 6 qty 01 Nos
9) Sensor connector cap 2 Nos
10) Operation/ maintenance manual 01 Nos
11) Case 01 Nos
12) Field operation guide 01 Nos
13) Life detector Display interface 01 Nos
14) Seismic sensor, #1,#2,#3,#4,#5,#6 all number sensor one each &
Acoustic sensor #1, 01 Nos
15) Head Phone with boom Mic 02 Nos
16) Sensor connecting cable 10 M on spool 6 Nos
17) Sensor Connecting cable ,3M 1 Nos