5.DIGITAL VHF REPEATER SET (PORTABLE RADIO)
Category: Collapsed Structure Search & Rescue (CSSR) Equipment
Color: ,
Size: ,
SlNo PARAMETER SPECIFICATION
1 General
i) Frequency Range 136 - 174 MHz (Full
band)
Functional check: B.O.O. will check operation
of radio set by programming lowest, highestand
any random frequency in 136-174 MHz
range with the help of measuring instruments.
ii) No of Channel
Capacity
16 or more BOO will check all these parameters one by one
with the help of standard testing instruments. If
the standard test instruments are not available
then firm must produce certificate of any Govt.
accredited lab or National Accreditation Board
for Testing and Calibration Laboratories
(NABL) approved laboratory or
International Laboratory Accreditation
Corporation (ILAC) approved laboratory.
iii) Channel spacing 12.5 KHz or better
iv) Frequency stability ±1.5 PPM or better
v) Protocol &
Technology
DigitalDMR (TDMA)
Technology.
BOO will check all these parameters with the
help of standard testing instruments. If the
standard test instruments are not available then
firm must produce certificate of any Govt.
accredited lab or National Accreditation Board
for Testing and Calibration Laboratories
(NABL) approved laboratory or International
Laboratory Accreditation Corporation (ILAC)
approved laboratory
vi) Type of Emission
(Modulation)
Analog : 11K0F3E
Digital : 4FSK or
equivalent technique
complying to open
standard /
nonproprietary Digital
Protocol as defined by
an international
standard body like
ETSI/FCC etc.
BOO will check all these parameters with the
help of standard testing instruments. If the
standard test instruments are not available then
firm must produce certificate of any Govt.
accredited lab or National Accreditation Board
for Testing and Calibration Laboratories
(NABL) approved laboratory or International
Laboratory Accreditation Corporation (ILAC)
approved laboratory.
vii) Weight Less than 15 Kg BOO will check practically to measure weight
by weighing machine.
viii) Power source i) DC -13.8 Volt +
15%
ii) AC – 230 Volt +
15%, 50Hz
iii) There should be
provision to shift
automatically on DC
supply during mains
failure & when mains
Apply 230 VAC ±15% and 13.8 VDC ±15%
one by one and check that whether set is
working properly or otherwise.
155
supply restored it
should be shifted on
mains from DC supply
ix) Protection (i) Reverse polarity
protection
(ii) Protection against
high VSWR
i) BOO will check it by connecting Radio set
with DC supply in reverse polarity and
switch the set to“ON’ position. There should
not be any harm to the Radio Set.
ii) BOO set be switched “ON’ removing
antenna/dummy load and PTT be pressed.
In such a condition there should not be any
harm to Radio set.
2 Transmitter
i) RF Power output 45 Watt or more
(programmable /
Selectable)
B.O.O. will check all these parameters in the
entire frequency range mentioned in the QRwith
the help of standard testing instruments. If the
standard test instruments are not available then
firm must produce certificate of any Govt.
accredited lab or National Accreditation Board
for Testing and Calibration Laboratories
[NABL] approved laboratory or International
Laboratory Accreditation Corporation (ILAC)
approved laboratory.
ii) FM Hum & Noise -40 dB or better
iii) Modulation
Limiting
+ 2.5 KHz @ 12.5
KHz
iv) Adjacent Channel
Power
-60 dB or better
v) Audio Distortion Less than 3%
3 Receiver
i) Sensitivity i) Analog :- 0.30 μV
(12 dB SINAD ) or
better
ii) Digital :- 0.30 μV at
5% BER or better
B.O.O. will check all these parameters in the
entire frequency range mentioned in the QRwith
the help of standard testing instruments. If the
standard test instruments are not available then
firm must produce certificate of any Govt.
accredited lab or National Accreditation Board
for Testing and Calibration Laboratories
[NABL] approved laboratory or International
Laboratory Accreditation Corporation (ILAC)
approved laboratory.
ii) Selectivity
(Adjacent Chanel )
60 dB or better
iii) Inter-modulation 70 dB or better
iv) Audio Response +1,-3 dB
v) Rated Audio
Distortion
Less than 3%
4 ENVIRONMENTAL SPECIFICATION
i) Operating
Temperature
-300C to +600C Firm must produce certificate of any
Government accredited Lab. or NABL or ILAC
ii) Storage approved laboratory.
Temperature
-400C to +700C
iii) Humidity Max. 95% @ +400C
non-condensing.
5 Networking Should be capable to
support IP site
connects.
Firm will show Networking and interfaces
related function of repeater practically by
connecting it in user organization network.
6 Interfaces Ethernet port RJ-45 to
provide
a) Wide area IP
connectivity for Voice
and Data.
b) Remote monitoring
and status check.
7 Accessories
Battery cable &
Mounting fixtures
Should be supplied
with Repeater
B.O.O. will check it practically by connecting
battery cable & mounting fixtures with
repeater.
Antenna i) 3dB/6dB gain Omni
directional antenna
BOO will check it practically by connecting
with 45 meter RF
Cable RG-217 for base
station will beprovided
as per quantity
mentioned
in list of store.
transmission there should be no mismatch
between radio and antenna.
Programming kit All necessary
programming software
and hardware required
for the set will be
provided as per
quantity mentioned
in list of store.
BOO will check it practically that all necessary
programming software and hardware are
available as per user requirement.
Literature i) User’s manual with
each radio sets should
be provided free ofcost
in soft as well as hard
copy.
ii) Technical repairing
manual with complete
block diagram, circuit
layout etc should be
provided in soft as well
as hard copy as per
quantity
mentioned in list of
store.
BOO will check it physically that user and
technical manual are available as per user
requirement.
8
Field Trial The actual
performance of the
radio set will be
assessed.
Field trial of equipment will be conducted by a
Board of Officers in the operational area of the
force in the presence of Vendor/representative of
firms to ascertain the user satisfaction beforethe
proposal is accepted. Radio equipment withall
required accessories will be provided by the
participating firm’s on “No Cost No
Commitment” basis at the indenter discretion